An Improved Reaerosolization Test Device: Its Design, Operation and Capabilities.
Document
An Improved Reaerosolization Test Device: Its Design, Operation and Capabilities.
Copies
1 Total copies, 1 Copies are in, 0 Copies are out.
The purpose of the report is to describe the design, operation, and capabilities of an improved laboratory test device that is intended to simulate the reaerosolization of a powder in the field. The improved apparatus was tested with various CS2, resorcinol, and para-aminobenzoic acid powders (particle sizes between 2 and 15 microns MMD) at a range of airflow rates and was found to give a linear relationship between airflow rates and percent reaerosolization.